AS/NZS 4257.6耐沖擊性測試,南京睿督公司專業(yè)提供澳洲NATA資質(zhì)的AS/NZS 4257.6塑料屋頂及墻面覆蓋層材料耐沖擊性測試,更多關(guān)于澳標(biāo)AS/NZS 4257.6耐沖擊性測試,請咨詢南京睿督公司,免費(fèi)咨詢電話:025-8658 3475。
AS/NZS 4257.6 塑料屋頂及墻面覆蓋層材料-測試方法,耐沖擊性測試
AS/NZS 4257.6 Plastic roof and wall cladding materials-Methods of test, Method 6: Determination of impact resistance
AS/NZS 4257.6耐沖擊性測試評定
Compare the number of strikes with the number of broken test specimens. The results shall be interpreted as follows:
1) if the true impact rate falls within Region C(TIR above 10%), the result shall be reported as a failure.
2) if the true impact rate falls within Region A(TIR above 10%), the result shall be reported as a Pass.
3) if the result falls in Region B, the result is indeterminate. In this case, testing shall be continued until a positive result is obtained or until it becomes clear that a result in Region A is most unlikely, in which case, the result shall be reported as a failure.